Adjustable Transarticular Frame Using Standard SK ESF Components
A popular technique for spanning joints with all sizes of SK ESF frames is the utilization of modified single SK ESF clamps to form an adjustable articulation that is quite secure.
Read moreModifying an Angular Hinge for Transarticular ESF
Several customers utilize the angular hinge of the circular external skeletal fixation system to construct a simple, non-locking hinged fixator for temporary use across joints. When used in this fashion...
Read morePin Tract Release Incision Using Mini Gelpi Retractors
The minimum release incision size should be that which yields no soft tissue tension on the pin at any point during full flexion and extension of the joints above and below the fixator pins.
Read moreUnicondylar Fracture Repair Using Miniature Stick-Pins
Miniature stick-pins are useful for stabilizing condylar fractures of the distal humerus in small (<5 kg), young animals. They have more holding power in the soft bone...
Read moreSurgery-Friendly Draping Method
Manipulation of limbs during orthopedic procedures relies on drapes being free to move. Unfortunately, drapes often do not realign...
Read moreSimplified Countersinking of an IM Pin
Countersinking of intramedullary pins is occasionally required in femoral, tibial, and humeral fractures to minimize morbidity due to joint interference or soft tissue impingement...
Read morePatient Positioning for Mandibular Fracture Repair
Positioning a patient with a mandibular fracture for optimal access to the oral cavity, ensuring proper reduction/dental occlusion, and placing implants easily can be challenging.
Read moreSeparating ESF Pins within ESF Packs
Consider using a syringe case to segregate ESF pins within ESF packs. Keeping different diameters...